Chapter 5 Function parameter
46
Ch
ap
ter 5
242 F7.38 Random arrivals current 2
0.0% to 300.0% (rated motor
current)
-100.0%
☆
243 F7.39
Random arrivals current 2
width
0.0% to 300.0% (rated motor
current)
0.0%
☆
244 F7.40 Module temperature arrival 0
℃
to 100
℃
75
℃
☆
245 F7.41 Cooling fan control
0: Fan running only when running
1: Fan always running
0
☆
246 F7.42 Timing function selection
0: Invalid 1: Valid
0
★
247 F7.43 Timing run time selection
0: F7.44 setting
1: AI1
2: AI2
3: Panel potentiometer Analog
input range corresponds to F7.44
0
★
248 F7.44 Timing run time
0.0Min to 6500.0Min
0.0Min
★
249 F7.45
Current running reaches the
set time.
0.0Min to 6500.0Min
0.0Min
★
250 F7.46 Awakens frequency
dormancy frequency(F7.48)to
maximum frequency (F0.19)
0.00Hz
☆
251 F7.47 Awakens delay time
0.0s to 6500.0s
0.0s
☆
252 F7.48 Dormancy frequency
0.00Hz to awakens
requency(F7.46)
0.00Hz
☆
253 F7.49 Dormancy delay time
0.0s to 6500.0s
0.0s
☆
254 F7.50
AI1 input voltage
protection lower limit
0.00V to F7.51
3.1V
☆
255 F7.51
AI1 input voltage
protection upper limit
F7.50 to 10.00V
6.8V
☆
256
F7.52~
F7.53
Reserve
257 F7.54 Jog mode setting3
Bits:
0: forward
1: reverse
2: determine the direction from the
main termina
Ten bits:
0: restore to the previous state after
jogging
1: stop running after jogging
Hundred bits:
0:recover to the previous
deceleration time after jogging
1: keep the deceleration time the
sameafter jogging
002
☆
5-1-10.F8 Group - Fault and protection
No.
Code
Parameter name
Setting range
Factory
setting
Chan-
ge
258
F8.00 Overcurrent stall gain
0 to 100
20
☆