Chapter 5 Function parameter
40
Ch
ap
ter 5
7
Anolog AI1
0V~10V(Or 0
~
20mA)
8
Anolog AI2
0V~10V(or 0~20mA)
9
Anolog AI3
0V
~
10V
10
Lentgh value
0~Max. setting length
11
The count value
0~Max. count value
12
Coummunication set
0.0%~100.0%
13
Motor speed
0~Max. output frequency correspondent speed
14
Output current
0.0A~100.0A(Inverter
power
≦
55kW)
;
0.0A~1000.0A(Inverter power>55kW)
15
DC bus voltage
0.0V~1000.0V
16
Reserve
Reserve
17
Frequency source main set
0~Max. output frequency
127 F2.09
Maximum output frequency of high-
speed pulse
0.01kHzto 100.00kHz
50.00k
Hz
☆
128 F2.10
SPB switching quantity output delay
time
0.0s to 3600.0s
0.0s
☆
129 F2.11 Relay 1 output delay time
0.0s to 3600.0s
0.0s
☆
130 F2.12
Expansion card DO output delay
time
0.0s to 3600.0s
0.0s
☆
131 F2.13 SPA output delay time
0.0s to 3600.0s
0.0s
☆
132 F2.14 Relay 2 output delay time
0.0s to 3600.0s
0.0s
☆
133 F2.15
DO output terminal active status
selection
Units digit: SPB switching
quantity
0: positive logic
1: anti-logic
Tens digit: Relay 1
Hundreds digit: Hundreds
digit: Undefined
Thousands digit: SPA
Ten thousands digit: Relay 2
00000
☆
134 F2.16 DA1 zero bias coefficient
-100.0% to +100.0%
0.0%
☆
135 F2.17 DA1 gain
-10.00 to +10.00
1.00
☆
136 F2.18 DA2 zero bias coefficient
-100.0% to +100.0%
20.0%
☆
137 F2.19 DA2 gain
-10.00 to +10.00
0.80
☆
5-1-5.F3 Group - Start and stop control group
No. Code
Parameter name
Setting range
Factory
setting
Chan-
ge
138 F3.00 Start-up mode
0: Direct startup
1: Speed tracking restart
2: Pre-excitation start (AC
asynchronous motor)
0
☆
139 F3.01 Speed tracking mode
0~2: reserve
3: Rotate speed tracking method3
3
★
140 F3.02 Speed tracking value
1 to 100
20
☆