Chapter 5 Function parameter
45
Ch
ap
ter 5
between deceleration time 1
and deceleration time 2
frequency)
220 F7.16
Forward/reverse rotation
deadband
0.00s to 3600.0s
0.00s
☆
221 F7.17 Reverse rotation control
0: Enable 1: Disable
0
☆
222 F7.18
Set frequency lower than
lower limit frequency mode
0: running at lower limit frequency
1: stop
2: zero speed running
0
☆
223 F7.19 Droop control
0.00Hz to 10.00Hz
0.00Hz
☆
224 F7.20
Setting cumulative power-on
arrival time
0h to 36000h
0h
☆
225 F7.21
Setting cumulative running
arrival time
0h to 36000h
0h
☆
226 F7.22 Start protection selection
0: OFF 1: ON
0
☆
227 F7.23
Frequency detection value
(FDT1)
0.00Hz to F0.19(maximum
frequency)
50.00Hz
☆
228 F7.24
Frequency detection
hysteresis value (FDT1)
0.0% to 100.0% (FDT1 level)
5.0%
☆
229 F7.25
Frequency reaches
detection width
0.00 to 100% (maximum
frequency)
0.0%
☆
230 F7.26
Frequency detection value
(FDT2)
0.00Hz to F0.19 (maximum
frequency)
50.00Hz
☆
231 F7.27
Frequency detection
hysteresis value (FDT2)
0.0% to 100.0% (FDT2 level)
5.0%
☆
232 F7.28
Random arrivals frequency
detection value 1
0.00Hz to F0.19 (maximum
frequency)
50.00Hz
☆
233 F7.29
Random arrivals frequency
detection width 1
0.00% to 100.0% (maximum
frequency)
0.0%
☆
234 F7.30
Random arrivals frequency
detection value 2
0.00Hz to F0.19 (maximum
frequency)
50.00Hz
☆
235 F7.31
Random arrivals frequency
detection width 2
0.00% to 100.0% (maximum
frequency)
0.0%
☆
236 F7.32 Zero current detection level
0.0% to 300.0% (rated motor
current)
5.0%
☆
237 F7.33
Zero current detection
delay time
0.01s to 360.00s
0.10s
☆
238 F7.34
Overrun value of output
current
0.0% (not detected)
0.1% to 300.0% (rated motor
current)
200.0%
☆
239 F7.35
Output current overrun
detection delay time
0.00s to 360.00s
0.00s
☆
240 F7.36 Random arrivals current 1
0.0% to 300.0% (rated motor
current)
-100.0%
☆
241 F7.37
Random arrivals current 1
width
0.0% to 300.0% (rated motor
current)
0.0%
☆