Chapter 5 Function parameter
44
No. Code Parameter name
Setting range
Factory
default
Change
Reference
page
206.
b0.08
Motor stator and
rotor inductance
0.1 to 6553.5mH
Depends
on models
☆
87
207.
b0.09
Motor stator and
rotor mutual
inductance
0.1 to 6553.5mH
Depends
on models
☆
87
208.
b0.10
Motor no-load
current
0.01 to 655.35A
Depends
on models
☆
87
209.
b0.11
Motor parameter
auto tunning
0: no operation
1: Motor parameters
comprehensive auto
tunning
2: Motor parameters
static auto tunning
0
★
88
5-1-19.
y0 Group - Function code management
No.
Code
Parameter name
Setting range
Factory
default
Change
Reference
page
210.
y0.00
Function parameter
recovery
0: no operation
1: Restore
defaults
2: Clear fault
history
3: Backup
parameters
4: Restore from
backup
0
★
88
211.
y0.01 User password
0 to 65535
0
★
89
5-1-20.
y1 Group - Fault history search
No.
Code
Parameter name
Setting
range
Factory
default
Change
Reference
page
212.
y1.00 Type of the first two faults 0 to 22
0
●
89
213.
y1.01 Type of the first fault
0 to 22
0
●
89
214.
y1.02 Type of current fault
0 to 22
0
●
89
215.
y1.03
Running frequency of
current fault
0.00Hz
●
90
216.
y1.04
Output current of current
fault
0.0A
●
90