Chapter 3 Keyboard
18
level menu) → function code (second level menu) → function code settings (third level
menu) . The operation flow is shown in the figure.
Description: return to the second-level menu from the third-level menu by pressing PRG
key or ENTER key. The difference between the two keys : press ENTER to return the
second-level menu and save parameters setting before returning, and automatically
transfer to the next function code; press PRG to return directly to the second-level menu,
do not save parameters setting,and return to current function code .
Example 1 :restore factory default
50.00
PGR
y0
ENTER
y0.00
0
1
d0
50.00
ENTER
ENTER
Example 2 :change function code F0.01 from 50.00Hz to 40.00Hz
50.00
PGR
F0
ENTER
F0.00
F0.01
F0
F0.02
40.00
50.00
SHIFT
40.00
50.00
d0
PGR
ENTER
PGR
PGR