background image

15. Ensure that generator is properly grounded. (See

“Grounding the generator” section in this manual.)

16. Do not wear loose clothing, jewelry, or anything that

may be caught in the starter or other rotating parts.

17. Unit must reach operating speed before electrical loads

are connected. Disconnect loads before turning off
engine.

18. To prevent surging that may possibly damage

equipment, do not allow engine to run out of fuel when
electrical loads are applied.

19. When powering solid state equipment, a Power Line

Conditioner should be used to avoid possible damage to
equipment.

20. Do not stick anything through ventilating slots, even

when the generator is not operating. This can damage
the generator or cause personal injury.

21. Before transporting the generator in a vehicle, drain all

fuel to prevent leakage that may occur.

22. Use proper lifting techniques when transporting the

generator from site to site. Improper lifting techniques
may result in personal injury.

23. To avoid burns, do not touch engine muffler or other

engine or generator surfaces which became hot during
operation.

24. Do not alter or modify the heat shield.

SPARK ARRESTER

YOUR  PRODUCT  MAY  NOT  BE    EQUIPPED  WITH  A 

SPARK  ARRESTING  MUFFLER.

    If  the  product  will  be  used 

around flammable materials, such as agricultural crops, forests,
brush, grass, or other similar items, then an approved spark arrester should 
be  installed  and  is  legally  required  in  the  State  of  California.  The 
California statutes requiring a spark arrester are Sections
13005(b), 4442 and 4443.  Spark Arresters are also required on some 
U.S. Forest Service land and may also be legally required under other 
statutes and ordinances.  An approved spark arrester is available from 
our product dealers, or may be ordered from Pramac America, 
P.O. Box 6001, Kearney, Nebraska 68848.  1-800-445-1805.  Spark 
arresters can also be ordered from our website, www.powermate.com.

English 

4

DETERMINING TOTAL WATTAGE

In order to prevent overloading and possible damage to your 

generator it is necessary to know the total wattage of the connected load.  
To determine which tools and/or appliances your generator will run follow 
these steps:

1.

Determine if you want to run one item or multiple items
simultaneously.

2.

Check wattage requirements for the items you will be
running by referring to the load’s nameplate or by
calculating it (multiply amps x volts = watts).

3.

Total the watts for each item. If the nameplate only gives
volts and amps, multiply volts x amps = watts.

1 KW = 1,000 watts.

4.

Motorized appliances or tools require more than their rated
wattage for start up.

NOTE:  Allow 2 1/2 to 4 times the listed wattage for
starting equipment powered by electric motors.

5.

The generator’s rated watts should match or exceed the
total number of watts required for the equipment you want
to run.

6.

Always connect the heaviest load to the generator first,
then add other items one at a time.

NOTE: Additional information on determining wattage
requirements can be found on our website:

www.powermate.com

.

OPERATING VOLTAGE

CAUTION:    Operating  voltage  and  frequency  requirement  of 
all  electronic  equipment  should  be  checked  prior  to  plugging 
them into this generator. Damage may result if the equipment
is not designed to operate within a +/- 10% voltage variation, 
and +/- 3 hz frequency variation from the generator name 
plate ratings. To avoid damage, always have an additional
load plugged into the generator if solid state equipment (such as a 
television set) is used.  Apower line conditioner is recommended 
for some solid state applications.

A  power  line  conditioner  should  be  used  when  running  one  or 

more of the following solid state items:

Garage door openers
Kitchen appliances with digital displays
Televisions
Stereos
Personal computers
Quartz clocks
Copy machines
Telephone equipment

Other solid state equipment may require a power line 

conditioner.  For more information, contact our Customer Service 
Department at 1-800-445-1805 or www.powermate.com.

Customer Hotline 1-800-445-1805 

Summary of Contents for 62929

Page 1: ...model and serial numbers as indicated on your Generator s nameplate Model No _________________ Serial No __________________ Enregistrer le code du mod le et le num ro de s rie figurant sur la plaque s...

Page 2: ...urateur 14 Carburant 12 Trucs de d marrage rapide 14 C ble d installation de l appareil 12 Usage et entreposage 14 D marrage de l appareil 12 Usage peu fr quent 14 Pr paratifs au d marrage 12 Entrepos...

Page 3: ...generator in a well ventilated area with the fuel tank empty Fuel should not be stored near the generator English 12 Your generator should never be operated under these conditions a Uncontrolled chang...

Page 4: ...nglish 4 DETERMINING TOTAL WATTAGE In order to prevent overloading and possible damage to your generator it is necessary to know the total wattage of the connected load To determine which tools and or...

Page 5: ...off the main switch Before making permanent connections a double throw transfer switch must be installed To avoid electrocution or property damage only a trained electrician should connect generator...

Page 6: ...verfill the tank Keep maximum fuel level 1 4 inch below the top of the fuel tank This will allow expansion in hot weather and prevent overflow CORD SET WIRING If your generator is supplied with a 4 wi...

Page 7: ...cified in parts list Other brushes may appear to be identical but may have completely different mechanical and electrical characteristics EXCITING THE GENERATOR NOTE If your generator is a brushless u...

Page 8: ...ays using a fuel stabilizer A fuel stabilizer will minimize the formulation of fuel gum deposits during storage The fuel stabilizer can be added to the gasoline in the fuel tank or into the gasoline i...

Page 9: ...boue ou autre mati re trang re 10 Les rallonges les cordons d alimentation et tout appareil lectrique doivent tre en bon tat Ne jamais faire fonctionner un appareil lectrique dont le cordon d aliment...

Page 10: ...sse www powermate com D TERMINATION DE LA PUISSANCE TOTALE N CESSAIRE Afin d viter la g n ratrice la surcharge et les dommages possibles il faut conna tre la puissance totale de la charge branch e Pou...

Page 11: ...permanentes installer un commutateur de transfert deux directions Pour viter toute lectrocution ou des dommages mat riels faire connecter le g n rateur l installation lectrique de la maison par un le...

Page 12: ...condition qu elle ait un indice d octane lev 85 octane minimum Il est recommand d utiliser en tout temps le stabilisateur de carburant ce qui permettra de r duire la formation de d p ts de gomme dans...

Page 13: ...moteur doit tre rang ou transport 6 Si l on utilise un couvercle ne l installez pas jusqu ce que l appareil soit refroidi Ne pas brancher un appareil puissant sur le g n rateur pendant la p riode de...

Page 14: ...burateur et le r servoir de toute essence ENTREPOSAGE A LONG TERME Si le groupe lectrog ne n est pas utilis ou qu il est remis pendant plus d un mois proc der comme suit 1 Remettre de l huile jusqu au...

Page 15: ...or en un lugar con buena ventilaci n con el tanque de combustible vac o No se debe almacenar combustible cerca del generador Espa ol 15 12 Su generador no deber operarse jam s si ocurre do lo siguient...

Page 16: ...je total de la carga conectada Para determinar qu herramientas y o equipos electrodom sticos su generador har funcionar siga los pasos a continuaci n 1 Determine s desea hacer funcionar un aparato o v...

Page 17: ...r al sistema el ctrico residencial apague el interruptor principal Antes de hacer las conexiones permanentes debe instalarse un interruptor de transferencia de dos v as Para evitar la electrocuci n o...

Page 18: ...naje por lo menos 85 de octanaje de la bomba Recomendamos que siempre utilice un estabilizador para combustible Un estabilizador de combustible minimizar la formulaci n de dep sitos de goma de combust...

Page 19: ...tor descrito en el manual del motor Espa ol No aplique una carga el ctrica fuerte durante el per odo inicial de funcionamiento las primeras dos o tres horas de operaci n MANTENIMIENTO GENERADOR Escobi...

Page 20: ...burador y del tanque de gasolina ALMACENAMIENTO A LARGO PLAZO Cuando el equipo generador no se est operando o est almacenado durante m s de un mes siga las instrucciones siguientes 1 Vuelva a llenar d...

Reviews: