Installation and operator’s manual
Page 31 of 65
PVI-2000-OUTD-AU Rev.: 1.0)
5
MONITORING AND DATA TRANSMISSION
5.1
User Interface Mode
WARNING
: The RS-485 wire must ensure a protection of at least 600V.
The AURORA inverter usually works automatically and is maintenance-free.
When solar radiation is not high enough to provide power for export to the grid
(during night time, for example) AURORA disconnects automatically, and enters
the stand-by mode, waiting to start working again. The operational cycle is
automatically restored as soon as the solar radiation is enough.
AURORA inverter can provide operational data in the following ways:
¾
LED indicators
¾
Operational data on the LCD display
¾
Data transmission on a dedicated serial RS-485 line or RS-232 line. The data can
be collected by a PC or data logger equipped with a suitable RS-485 or RS-232
port. In case you use the RS-485 line, a RS-485/RS-232 AURORA serial
interface converter model number PVI-RS232485 can be useful. You can also
use the AURORA Easy Control (*) data logger.
(*) Please check if this accessory is available with your installer or retailer.