Automatic boiler for wood pellets
Instructions for installation and operation
56
TECHNICAL INFORMATION
NUMBER 005/2006
Technical change: BOILERS OF KPxx FAMILY HAVE BEEN EQUIPPED WITH O GSM MODEM
Properties achieved:
The GSM modem installed on boilers increases the comfort level of operation. The system of automatic reporting of error
conditions guarantees quick service intervention. The system makes it possible to monitor a network of boiler rooms.
The following has been added to the electric equipment of the boiler:
- Connector CANNON 9 FEMALE placed on the subpanel on the rear side of the boiler - see the figure number
Ti001/1.
- Interconnection of the connector with the control unit - see the figure number Ti001/3.
- GSM modem.
- Communication module fitted in the base inside the control unit - see the figure number Ti005/1.
Mechanical arrangement:
Figure number Ti005/1
The microwave aerial is equipped with a magnet for easy fastening.
Description of operation:
The software package of the control unit is enlarged with the programme routines to receive and emit short text
messages.
A set of defined commands which ensure simple control of the boiler:
STATUS
– this command will be responded by the control unit with information on the momentary operating
conditions.
START
– this command will put the boiler into operation (the virtual contact of the room thermostat is
permanently connected).
STOP
– this command will put the boiler into the attenuation state (the virtual contact of the room thermostat is
permanently disconnected).
NORMAL
– the command after which the state of the real room thermostat is accepted by the boiler.
Note:
After any push-button of the control unit is depressed by the operator, the control unit will
also get to the mode ignoring remote control commands.
Note:
The control unit communicates only with telephone numbers adjusted by the operator and
by the service organization.
Summary of Contents for KP 10
Page 1: ......