Automatic boiler for wood pellets
Instructions for installation and operation
57
Note:
: Structure of the text message sent by the control unit is as follows:
DISPLAY="AUTO 12:20" T=040 RT=1 HT=0 MODULATION=0 Fon=05 Foff=30 FAN=056 "256,60"
with the following meaning:
DISPLAY="AUTO 12:20"
state - displayed on the control unit display
T=040
boiler water temperature
RT=1
switched in room thermostat
HT=0
disconnected thermostat of the heater (HUW)
MODULATION=0
modulation turned off
Fon=05
momentary adjustment - feeder 1 turned on 5 s
Foff=30
momentary adjustment - feeder 1 turned off 30 s
FAN=056
momentary adjustment of the fan 56 %
"256,60"
balance of credit on the SIM card
Note:
Structure of the failure text message sent by the control unit is as follows:
Display State
STOP
displayed on the display of the control unit
STOP-TEMP.
>
95
°
C
displayed on the display of the control unit
STOP-TEMP.
>
100
°
C
displayed on the display of the control unit
STOP-IGNITE FAIL
displayed on the display of the control unit
BLOCKED FEEDER 1
displayed on the display of the control unit
BLOCKED FEEDER 2
displayed on the display of the control unit
SW modification:
In the menu
12.Setup
12.1. User
[PIN]
1) the following menu has been added 12.1.5.
GSM modem
Enabled
the selected command will be confirmed by the key
ENTER
the control unit will confirm acceptance of the command by short blink and by the following notification:
Enabled
and resumes the work with the adjusted telephone numbers, processes incoming text messages and send
information on the operating state of the boiler or failure messages.
Note:
The modem has to be connected on power supply voltage before (at the same time) the control unit
is turned on.
Note:
The control unit has to be turned off and on after the work with modem has been permitted. The
control unit will initiate connection with the modem.
Having the modem been initiated, the unit will notify connection with a short message
searching GSM:
GSM conect
If the connection with the modem is not functional (error in connection or missing power supply), the control unit will
notify this fact with a short message
GSM not conect
if we choose the command
Disabled
and confirm the selected command with the key
ENTER
the modem will not be initiated and the function of messages control via the GSM is prohibited.
Note:
The SIM card placed in the modem may not be locked with PIN code.
Note:
The SIM card is not a part of the delivery.
Summary of Contents for KP 10