Automatic boiler for wood pellets
Instructions for installation and operation
47
Table 6
Setting Control Unit from productions
1
Fan
42%
2
Temperature
80°C
3
Feeder 1 ON
5 s
4
Feeder 1 OFF
45 s
5
Advance Feeder 2
1 s
6
Run-in Feeder 2
5 s
7
Fall time
45 min
Programs
kW
Feeder 1 ON
Feeder 1 OFF Advance Feeder2 Run-in Feeder2
Fan
Fall time Temperature
P 1
4,5
3
80
1
5
30
45
80
P 2
8,3
5
75
1
5
34
45
80
P 3
12,0
5
50
1
5
38
45
80
P 4
13,5
5
45
1
5
42
45
80
P 5
15,0
5
38
1
5
46
45
80
P 6
13,5
5
45
1
5
42
45
80
9
El. Heating
No
10
El. Ignition
No
1
Fan
64%
2
Temperature
80°C
3
Feeder 1 ON
5 s
4
Feeder 1 OFF
25 s
5
Advance Feeder 2
1 s
6
Run-in Feeder 2
5 s
7
Fall time
45 min
Programs
kW
Feeder 1 ON
Feeder 1 OFF Advance Feeder2 Run-in Feeder2
Fan
Fall time Temperature
P 1
7,5
5
90
1
5
30
45
80
P 2
13,5
5
45
1
5
45
45
80
P 3
20,0
5
29
1
5
53
45
80
P 4
22,5
5
25
1
5
64
45
80
P 5
25,0
5
22
1
5
75
45
80
P 6
22,5
5
25
1
5
64
45
80
9
El. Heating
No
10
El. Ignition
No
1
Fan
75%
2
Temperature
80°C
3
Feeder 1 ON
10 s
4
Feeder 1 OFF
20 s
5
Advance Feeder 2
1 s
6
Run-in Feeder 2
5 s
7
Fall time
45 min
Programs
kW
Feeder 1 ON
Feeder 1 OFF Advance Feeder2 Run-in Feeder2
Fan
Fall time Temperature
P 1
14,5
10
80
1
5
30
45
80
P 2
26,5
10
40
1
5
50
45
80
P 3
39
10
24
1
5
60
45
80
P 4
44,5
10
20
1
5
75
45
80
P 5
49
10
17
1
5
90
45
80
P 6
39
10
24
1
5
60
45
80
9
El. Heating
No
10
El. Ignition
No
KP 10
Feeder 1 with endless screw, Burner No.20
8
KP 20
Feeder 1 with endless screw, Burner No.20
8
KP 50
Feeder 1 with endless screw, Burner No.20
8
Summary of Contents for KP 10