53
Replacing the Diaphragm Blade Assembly
•
Secure the Diaphragm Blade Assembly to the Base Ring with four screws
(Figure 3-23).
Figure 3-23. Replacing the diaphragm blade assembly
•
From the front of the Shutter, replace the lower E-Ring “a” on the Aperture Link Lever
pin (Figure 3-24).
•
Reconnect the Aperture Control Lever link “b” to the pin and secure it with a second
E-Ring “C”.
Figure 3-24. Reconnecting the aperture link lever and aperture control lever