Copyright Planika Sp. z o.o.
www.planikafires.com
IG0058#00
31.03.2017
9
4.
USAGE
Before first use of the fireplace, make sure that all connections of individual elements of the system have been made
according to the instructions. Incorrect connection of system components for gas or faulty connection concentric air
combustion system may cause an improper operation of the device or damage it.
4.1.
First use
The first time you turn on the fireplace VALENTINO, it is necessary to use it at the maximum level of the flame for few
hours so that the elements warm themselves, and possible small residues of paints, coatings and lubricants will
evaporate. During this period, additional ventilation and ventilation of the room where the appliance is installed is
recommended, because the characteristic smell of evaporating powder paint may be felt for about another hour of
use. It can be particularly sensitive to volatile vapors may be pets (mainly birds).
If during your first startup of the device, sediment will appear on the inner surface of the glass (glasses), turn off the
device and allow it to cool to room temperature, and then clean the glass (see section 11. 1). The formation of the
RAID is caused by burning volatile components of paints, which initially may also have an impact on the image of the
flame.
Fireplace installed in the housing should be fired for the first time after complete drying of all the walls of housing.
This prevents the formation of cracks due to shrinkage of the materials. If the walls of the fireplace housing are made
of stone materials, leave it to dry for at least 6 weeks prior putting the unit into operation.
4.2.
Discoloration of walls and ceilings
When using gas heating, you can meet with a phenomenon of electrolytic colouring of walls and ceilings. It is caused
by the movement of air convection, and dust particles contained therein. Brown discoloration may also occur during
combustion of substances as a result of inadequate ventilation, smoking, the use of candles and oil lamps. These
problems can be partially prevented by ensuring adequate ventilation the room in which the device is located.