9.
SIGNAL QUALITY
To check the quality of the signal between the transmitter (remote control) and the receiver located in the mounting
bracket together with the gas valve and the control unit, you should press simultaneously buttons
and
.
The screen will show the RSSI value (received signal strength indicator), which means:
•
from -20 to-80 – good received signal strength,
•
from -80 to -100 –Poor received signal strength. In order to improve the
signal strength you should place the remote control closer to the unit or
change the position of the receiver to minimize the possibility of receiving
unwanted radio signals.
In the event of a communication error between the remote and device, this error
will be indicated by a failure sign
and the flashing sign of lack of communication
on the remote's screen. Most likely, the distance between the device and the
remote control is too large and the remote should be placed closer to receiver. If the
error persists despite the change in the distance between the remote and the
receiver, you must again carry out the process of establishing communication code
(Section 5.1).
10.
TROUBLESHOOTING
WARNING!
Installation, repair and maintenance must be performed by trained installer with the appropriate
permissions, service company or gas supplier.
In case of any fault or failure an error code indicating the potential emergency
situations will display on the screen of the remote control. The display will show the
letter "F", after which you will see a two-digit error code. Full list of error codes is
shown in the table below, which presents a summary of any incident that may occur,
possible causes and ways to overcome them.