F08
No ionisation
No spark
Make sure that the distance between
the electrodes is 3-4 mm
Replace the ignition electrodes
Check if the cables for the ignition
electrode are connected correctly
No Gas
Make sure, there is a gas connection
Poor transfer of the flame from
the main burner
Check the position of the blocks of
wood / debris
If necessary, remove dust and dirt
from the holes of the burner
Extinguishing of the flame at
the ionization electrode
(braising or picking of the
flame)
Check the tightness of the fireplace
combustion chamber, proper
adhesion of glass to each other on the
edges, as well as correct position of
the seals and downforce strip
Check restrictor setting
Ionisation electrode not
inserted correctly
Place the electrode in the right place
Blocked ionization electrode
(measure ionization current
flow, when> 0 and <1.8 uA)
Remove any residue vermiculite or
debris from the burner
Faulty ionisation electrode
(measure ionisation current if 0
electrode is damaged)
Replace the ionisation electrode
Triggered shock sensor (shake)
Check the sensor connection. Check
whether the construction of the fire
housing has not been damaged
(cracked)
F12
There has been no
release of ESYS
ESYS under permanent blockade Wait half an hour until ESYS resets
itself
F13
Loss of flame when
only the main burner
is turned on
Too low gas pressure or no gas
in the system
Check the gas supply
Damage to the coil of the gas
valve
Replace the coil of the gas valve
Dławienie płomienia
Throttling flame
Check the patency of the combustion
air system
24 hour control
Reset using the remote control
F14
Loss of flame, when
both burners are
turned on
Too low gas pressure or lack of
gas in the system
Check gas supply
Damage the coil of the gas valve Replace the coil of the gas valve
Throttling of the flame
Check the patency of the combustion
air system