43
GEO:CS1
FAULT FINDING
FAULT FINDING TABLES
SYMPTOM
POSSIBLE CAUSE
SOLUTION
The breech sensor defaults after firing.
The breech sensor is dirty.
Clean the breech sensor.
The breech sensor is faulty.
Replace the breech sensor.
The breech sensor is out of place.
Re-install the breech sensor then check the alignment.
On power up, the right hand side of
the screen is not displayed and the
marker will not fire.
The trigger is permanently depressed.
Adjust the trigger until the selected trigger detection method
is de-activated when the
trigger is released.
The CS1 does not fire.
The CS1 is not powered on.
Power up the CS1 using the button on the back of the
CS1 grip frame.
The POPS is not fully engaged.
Pull the POPS bonnet back until it engages.
The battery quality or charge level is very low.
Install new high quality alkaline or lithium
batteries.
The
batteries are flat.
Replace the batteries.
The
DWELL parameter is set too low.
Increase the DWELL parameter.
The trigger is set-up incorrectly.
Adjust the trigger correctly to fully open and close the
micro/opto switch.
The solenoid is not plugged into the CS1 body PCB.
Plug
the solenoid wire into port on the CS1 body PCB.
The BS is enabled and there is no paint in the breech.
Fill the loader with paint.
Check that the rubber bolt tip is seated correctly.
The PCB is damaged.
Replace the PCB.
The solenoid valve is damaged.
Replace the solenoid valve.
Constant high velocity/
Unable to lower velocity to desired fps.
Output pressure of the preset regulator is too high.
Use a preset regulator with an output pressure below 650 psi.
Consult the preset regulator manufacturer for possible faults /
maintenance requirements.