5/18

4.3.2 Increase of number and load capacity of contacts

If necessary the number and the load capacity of output contacts can be increased by 
using external contactors with forcibly guided contacts

Feedback circuit for external contactors 

with automatic start

Feedback circuit for external contactors 

with manual or monitored start

K8

K7

K7

K8

F

-

+

Tx

Ix

24 Vdc

OS1

OS2

K8

K7

K7

K8

F

-

+

Tx

Ix

24 Vdc

OS1

OS2

In order to function correctly, any modules or PLCs connected to the OSx safety elec-
tronic outputs must be able to withstand cyclical deactivation tests performed on the 
same.

 5 INTERNAL WIRING DIAGRAM

P1

P2

T02 ... T14

T01

J46 ... J48

J45

F1B ... F2B

F1A

OS2

0V

...

OS8

24V

OS1

A3

A4

A1

A2

I16 ... I44

I15

 6 SIGNALLING

PWR  

LED

LEDs  

P1, P2

Possible fault cause

Off

Off

No power supply, incorrect connections, power wires cut, external fuses 
broken.
Module fault.

Green

Off

Normal operation.

Green

Red

Non-restorable fault.
Recommended action: try to restart the module. If the fault persists, send 
the module to be repaired.

Green

Red x 1

Blue x 1

Restorable fault: overcurrent on Tx or Ox outputs.
Recommended action: disconnect the semiconductor signalling outputs 
(Ox) and the test outputs (Tx) to check whether an external short circuit 
is present.

Green

Red x 1

Blue x 2

Restorable fault: problem detected on OSx (short circuit towards earth or 
positive pole, or else short circuit between two OSx).
Suggested action: Disconnect the safety outputs to check if there are any 
problems on the external connections of the OSx outputs.

Green

Red x 1

Blue x 3

Restorable fault: module temperature outside the limits.
Suggested action: restore module temperature to within permissible limits.

Green

Red x 1

Blue x 4

Restorable fault. No power on 24V-0V terminals.
Recommended action: Check the electrical connections

Green

Blue x N

Module entered ERROR state at the request of the application program. 
Error code N. Typically due to incorrect input conditions (external short 
circuits, status not permitted).
Suggested action: disconnect the inputs to find any short circuits. Check 
the documentation supplied with the application program for further 
details.

 7 INSTRUCTIONS FOR PROPER USE

7.1 Installation

 Attention: Do not exceed the tightening torque of the terminal screws specified 

in the present operating instructions.

 Attention: Observe the wiring of the terminals: incorrect wiring can damage the 

device which may result in loss of the safety function.

 Attention: This is a complex device, designed to provide safety functions to 

protect machine operators. The hardware and software of this device, external devices, 
general circuit design and building, are all essential if specific safety goals are to 
be reached. Therefore, only qualified operators with suitable knowledge of electrical 
systems and safety regulations should install this device and put it into service.
- Install only inside a cabinet with protection degree not less than IP54 according to 
EN 60529.
- Always affix the device with the specific DIN rail adaptor acc. to EN 60715. 
- Do not stress the device with bending and torsion. 
- Do not modify or open the device for any reason.
- The device carries out an operator protection function. Any inadequate installation 
or tampering can cause serious injuries and even death, property damage, and eco-
nomic losses.
- These devices must not be bypassed, removed or disabled in any other way. 
- If the machine where the device is installed is used for a purpose other than that 
specified, the device may not provide the operator with efficient protection.

- The safety category of the system (according to EN ISO 13849-1), including the 
safety device, also depends on the external components connected to it and their 
type.
- Before installation, make sure the device is not damaged in any part.
- Before commissioning, check the correct functioning of the module.
- Avoid excessive bending of connection cables in order to prevent any short circuits 
or power failures.
- Do not paint or varnish the device.
- Do not drill the device.
- Do not use the device as a support or rest for other structures, such as raceways, 
sliding guides or similar.
- Before commissioning, make sure that the entire machine (or system) complies with 
all applicable standards and EMC directive requirements.
- The documentation required for correct installation and maintenance is available 
online in various languages on the Pizzato Elettrica website.
- This device can only be installed and used if all these technical instructions and all 
safety regulations relevant for the application have been observed and implemented.
- Should the installer be unable to fully understand the documents, the product must 
not be installed and the necessary assistance may be requested from the manufac-
turer (see paragraph SUPPORT).
- Always attach the following instructions to the manual of the machine in which the 
device is installed.
- These operating instructions must be kept available for consultation at any time and 
for the whole period of use of the device.

7.2 Do not use in the following environments

- In environments where continual changes in temperature cause the formation of 
condensation inside the device.
- In environments where the application causes the device to be subjected to strong 
impacts or vibrations.
- In environments with the presence of explosive or flammable gases or dusts.
- In environments containing strongly aggressive chemicals, where the products used 
coming into contact with the device may impair its physical or functional integrity.
- Prior to installation, the installer must ensure that the device is suitable for use under 
the ambient conditions on site.

7.3 Maintenance and functional tests

 Attention: Do not disassemble or try to repair the device. In case of any malfunc-

tion or failure, replace the entire device.
- The device installer is responsible for establishing the sequence of functional tests 
to which the device is to be subjected before the machine is started up and during 
maintenance intervals. 
- The sequence of the functional tests can vary depending on the machine complex-
ity and circuit diagram, therefore the functional test sequence detailed below is to be 
considered as minimal and not exhaustive.
- Perform the following sequence of checks before the machine is commissioned and 
at least once a year (or after a prolonged shutdown):
1) Check that the safety module housing is undamaged and in good condition. If the 
housing is damaged, replace the entire device.
2) Check that all signalling LEDs are working.
3) Check that the electrical cables are firmly lodged inside the terminals and connectors.
4) Check that the module functions as required by the application program.
- The device has been created for applications in dangerous environments, therefore 
it has a limited service life. Although still functioning, after 20 years from the date 
of manufacture the device must be replaced completely. The date of manufacture is 
placed next to the product code (see paragraph MARKINGS).

7.4 Wiring

 Attention: Do not install the safety module if voltage is present. Power the device 

only when the electrical circuits have been completely realized according to the speci-
fications indicated in the OPERATION paragraph. The first time you start the machine 
ensure that there are no people close to hazardous areas.
- Check that the supply voltage is correct before powering the device.
- Keep the charge within the values specified in the electrical operation categories.
- Only connect and disconnect the device when the power is off.
- when using plug-in-type terminal blocks, they may only be plugged in or unplugged 
if no supply voltage is present.
- Discharge static electricity before handling the product by touching a metal mass 
connected to earth. Any strong electrostatic discharge could damage the device.
- Power the safety module and the other devices connected to it from a single SELV/
PELV source and in accordance with the applicable standards (applies only to ver-
sions with supply voltage 12 V and 24 V).
- Plug-in type connectors, and in particular those of the output contacts of relays 
(when installed) may be powered by high voltage. 
- It is recommended that the supply voltage of the safety module be electrically iso-
lated from the power section of the machine and the connection cables of the module 
be laid separately from the power cables.
- Always connect the protection fuse (or equivalent device) in series with the power 
supply for each device.
- Always connect the protection fuse (or equivalent device) in series to the safety 
electrical contacts.
- During and after the installation do not pull the electrical cables connected to the 
device. If excessive tension is applied to the cables, the device may be damaged.

7.5 Additional prescriptions for safety applications with operator protection 
functions

Provided that all previous requirements for the devices are fulfilled, for installations 
with operator protection function additional requirements must be observed.
- The utilization implies knowledge of and compliance with following standards: 
EN ISO 13849-1, EN 62061, EN 60204-1, EN ISO 12100. 
- In the risk analysis, take into account that in manual start mode a possible sticking of 
the start button can lead to an immediate activation of the module.
- If external expansion modules or contactors are used to expand the system's switch-

Summary of Contents for CS MP312-0

Page 1: ...un guasto In questo stato il modulo si pone in condizioni di sicurezza ossia con tutte le uscite di sicu rezza disattivate Guasto un guasto pu essere interno o esterno al modulo di sicurezza I guasti...

Page 2: ...eb Pizzato Elettrica Questo dispositivo deve essere installato ed usato solamente se tutte le presenti istruzioni tecniche e tutte le norme di sicurezza rilevanti per l applicazione sono state osserva...

Page 3: ...indicate fanno riferimento ai morsetti di alimentazione Ax vedi caso per caso ogni modulo della scheda dove sono presenti i morsetti di tipo Fx 9 7 Circuiti di ingresso disaccoppiati Jx Numero ingress...

Page 4: ...are deactivated Fault a fault can be internal or external to the safety module Internal faults are autonomously detected thanks to its redundant and self monitored structure An external fault can be...

Page 5: ...Should the installer be unable to fully understand the documents the product must not be installed and the necessary assistance may be requested from the manufac turer see paragraph SUPPORT Always at...

Page 6: ...oltage Ui 500 V Minimum duration of input signal 10 ms Input signal filtering yes maximum interference period 0 4 ms Maximum input resistance 100 Maximum input capacitance 470 nF to ground 470 nF betw...

Page 7: ...et tat le module se met dans des conditions de s curit savoir avec toutes les sorties de s curit d sactiv es D faillance une d faillance peut survenir l int rieur ou l ext rieur du module de s curit L...

Page 8: ...une installation et un entretien corrects est dispo nible en ligne en plusieurs langues sur le site de Pizzato Elettrica Cet appareil doit tre install et utilis uniquement si toutes les pr sentes ins...

Page 9: ...ffre R solution 0 1 Hz Temps minimum pour la d tection de l arbre arr t 1 s S paration galvanique oui Tension d isolement Ui 500 V NB Les valeurs de tension et de courant indiqu es se r f rent aux bor...

Page 10: ...ermittelt wird In diesem Status geht das Modul in den Sicherheits Zustand ber d h alle Sicherheits Aus g nge sind deaktiviert Defekt ein Defekt kann intern oder extern am Sicherheits Modul entstehen I...

Page 11: ...st Die Montage und Wartungsanleitungen sind online in verschiedenen Sprachen auf der Webseite von Pizzato Elettrica erh ltlich Das Ger t darf nur installiert und verwendet werden wenn die vorliegende...

Page 12: ...standserkennung 1 s Galvanische Trennung ja Isolationsspannung Ui 500 V NB Die angegebenen Str me und Spannung beziehen sich auf die Versorgungsklemmen Ax je nach Modul unterschiedlich der Platine auf...

Page 13: ...o del m dulo de seguridad cuando se detecta un fallo En este estado el m dulo se pone en el estado de seguridad es decir se desactivan todas las salidas de seguridad Fallo un fallo puede ser interno o...

Page 14: ...dad electromagn tica La documentaci n necesaria para una instalaci n y mantenimiento correctos est disponible en varios idiomas online en el sitio web de Pizzato Elettrica Este dispositivo se debe ins...

Page 15: ...ci n 0 1 Hz Tiempo m nimo para la detecci n de parada del eje 1 s Separaci n galv nica s Tensi n de aislamiento Ui 500 V NB Las tensiones y corrientes indicadas hacen referencia a los bornes de alimen...

Page 16: ...poruchy V tomto stavu se modul p epne do zabezpe en ho stavu tj deaktivuj se v echny bezpe nostn v stupy Porucha porucha bezpe nostn ho modulu m e b t intern nebo extern Intern poruchy jsou zji t ny a...

Page 17: ...e jsou dodr eny a im plementov ny v echny tyto technick pokyny a v echny bezpe nostn p edpisy t kaj c se dan aplikace Pokud instala n technik nedok e pln porozum t dokumentaci instalaci pro duktu pro...

Page 18: ...ly 0 8 V vyp 12 24 V zap Galvanick odd len ano Izola n nap t Ui 500V Minim ln doba vstupn ho sign lu 10 ms Filtrace vstupn ho sign lu Ano maxim ln doba filtrace 0 4 ms Maxim ln vstupn odpor 100 Maxim...

Reviews: