RS-485 Connection Between Fast Dome and Conversion Interface
TXD+ of conversion interface RS-485 jack connects to TXDI+ of 1
st
fast dome and connect TXD- to
TXDI-
Linking 2
nd
Fast Dome
TXDO+ of 1
st
dome RS-485 jack connects to TXDI+ of 2
nd
dome to TXDO- of 1
st
dome to TXDI- of 2
nd
dome. 64 fast domes can link through the connection as shown.
7.4 Fast Dome, DVR and Keyboard
The DVR System is an advanced digital recording product, with long recording time and easy searching
features. Telemetry remote control is twisted pair for data transmission to the fast dome. Fast dome can
be controlled directly from the control panel of the DVR or from keyboard.
Each DVR (Digital Video Recorder) can manage 16 video signals and via RS-485 to daisy connection 16
sets of fast dome camera.
RS-485 Connection Between Fast Dome and DVR
TXD+ of DVR RS-485 jack connects to TXDI+ of 1
st
fast dome and TXD- of DVR to TXDI- of the 1
st
fast
dome.
Linking 2
nd
Fast Dome
TXDO+ of 1
st
dome RS-485 jack connects to TXDI+ of 2
nd
dome to TXDO- of 1
st
dome to TXDI- of 2
nd
dome.
RJ-45 Connection Between DVRs
“Keyboard Out” of 1
st
DVR pass out RJ-45 jack connects to “Keyboard In” of 2
nd
DVR’s RJ-45 jack.
RJ-45 Connection Between DVR and Keyboard
“Keyboard In” of 1
st
DVR’s RJ-45 jack connects to RJ-45 jack of keyboard.