Appendix C - Emergency Factory Default
In certain circumstance, to restore the server to initial factory default state may be necessary, normally processed
through web page (Miscellaneous Operation). If the user can’t get into web page (e.g. Missing of Username and
Password information), then he could use Emergency Factory Default to restore the factory default.
Procedures as below:
1. Turn the power off
2. Connect GPIO Input 4 to GND with small wire or switch.
3. Turn the power on. When the Status LED starts to blink (orange) twice, and then open the wire or switch that
set GPIO Input 4 back to open immediately.
4. Server will restore the factory default and restart.
Note
: When status LED starts to blink during power up, if not to set GPIO Input 4 back to open within
3 seconds
,
server will continue the boot sequence and doesn’t retrieve the factory default.