Alarm Management
The 6 alarm inputs of each PIXORD NDC are corresponding with the first 6 preset positions. When an alarm signal
is triggered, the dome will go to the relevant position at 360 /sec. Make sure the first 6 preset positions are set to
desired alarm areas.
Alarm input can be set to NC (normally close) or NO (normally open) depends on alarm detector.
Please refer to page 7 for alarm switch setting.
Relationship Between Alarm Inputs and First 6 Presets
Alarm Input 1 will send the dome to Preset Position 1
Alarm Input 2 will send the dome to Preset Position 2
Alarm Input 3 will send the dome to Preset Position 3
Alarm Input 4 will send the dome to Preset Position 4
Alarm Input 5 will send the dome to Preset Position 5
Alarm Input 6 will send the dome to Preset Position 6
Alarm Response Mode
The PIXORD NDC alarm response can be set to Lock or Release mode.
Lock: dome remains at last alarmed preset point
Release: dome moves between alarmed points then reverts to prior status, such as auto pan.
Lock Mode
When an alarm is triggered, the dome will go to the relevant position at 360 /sec and the keyboard will audio alert
the user until it is canceled manually.
To manually cancel the alarm trigger: Push ALARM RESET key.
If more than one alarm is triggered, the PIXORD NDC will lock on the last alarm-triggered position.
Release Mode
Under Auto Pan Condition
When an alarm is triggered under Auto Pan, PIXORD NDC will go to the relevant position at 360 /sec.
After 60 seconds the alarm will be canceled automatically and back to Auto Pan mode. If more than
one alarm is triggered, the PIXORD NDC will moves between alarmed points every 5 seconds and
back to Auto Pan mode after 60 seconds.
Not Under Auto Pan Condition
When an alarm is triggered not under Auto Pan, the PIXORD NDC will go to the relevant position at
360 /sec. After 60 seconds the alarm will be canceled automatically, and dome will be back to first
preset position. If more than one alarm is triggered, the PIXORD NDC will move between alarmed
points every 5 seconds and back to first preset position after 60 seconds.
The audio alert for alarm trigger will remain on until it is manually canceled by push the
ALARM RESET key.
70
Summary of Contents for 261 series
Page 1: ......
Page 12: ...3 1 Indoor Installation Structural Drawing 3 Installation 12 ...
Page 13: ...3 2 Outdoor Installation Structural Drawing Pendant Mounting 13 ...
Page 14: ...3 3 Embedded Mounting False Ceiling 14 ...
Page 15: ...15 ...
Page 17: ...3 4 Attached Mounting Fixed Ceiling 17 ...
Page 19: ...3 5 Pendant Mounting External Housing 19 ...
Page 20: ...20 ...
Page 21: ...21 ...
Page 23: ...23 ...