4 2
Special installation (Wall embedding (vertically wall-embedding equipment))
3.4.6 Wall embedding (vertically wall-embedding equipment)
This display is designed to accommodate embedding in a wall. Since the allowable range of outside-air temperature
depends on the installation conditions. Please observe the following conditions:
1
Use a metal mounting fixture that does not block the side slits or the back ventilation holes, and attach at a
minimum of four points. To avoid breaking the PDP panel, limit any twisting or bending stress applied to the
display to 1 mm or less.
2
Do not use cable clamps for this installation method. Cable clamps can interfere with proper ventilation and
result in device failure.
3
Installation conditions and ambient operating temperatures:
(1) If the space behind the wall is open
C
A
A
Install the display with
the fan on top.
A
A
100
m m
100
m m
Exhaust
* The same conditions apply to the working temperature requirements for a speaker system (PDP-S03-LR).
PC-9800 (56.4Hz)
PC-9800 (70.1Hz)
A size VIDEO
Machintosh (66.7Hz)
VGA (60Hz)
VGA (72.8Hz, 75Hz)
A
<
60
0~40
°
C
0~40
°
C
0~40
°
C
60
≤
A
<
150
0~40
°
C
0~40
°
C
0~35
°
C
Working temperature requirements
100 mm
100 mm
Summary of Contents for PDA-4002
Page 5: ...5 Features ...
Page 21: ...21 Installation procedure ...
Page 57: ...57 Special installation Installation under the floor ...
Page 69: ...69 Mounting standard metal fixtures PDK 4001 ...
Page 75: ...75 Mounting standard metal fixtures PDK 4002 ...
Page 81: ...81 Mounting standard metal fixtures PDK 4004 ...
Page 131: ...131 Mounting standard metal fixtures Precautions for installing the optional speaker ...
Page 135: ...135 Before making adjustments ...