4.9 Wall hanging metal fixture for the plasma display : PDK-4006
4.9.1 Specifications
Outer dimensions
.............. 912 (W)
×
42 (D)
×
589 (H) mm
Weight
................................ 6.7 kg (metal fixture alone)
37.5 kg <38.3 kg> (metal fixture with two plasma displays PDP-V402 <PDP-V402E>)
Material
.............................. Steel pipe for general structures (STK-MR)
Treatment
........................... Semi-matt black paint
Package dimensions
.......... 885 (W)
×
270 (D)
×
80 (H) mm
Package weight
................. 7.6 kg
Accessories
Vertical frame ......................................................... 2 pcs (for the left side and the right side)
Lateral frame .......................................................... 2 pcs
Hexagonal socket frange bolt ................................. 8 pcs
Monitor fixing bolt .................................................. 4 pcs
Hexagonal wrench ................................................. 1 pc
Mounting standard metal fixtures (PDK-4006)
The operating environmental temperature must be kept within the range of 0 to 35
°
C when this fixture is used to
install the display. When the angle is 5 degrees or more, you may use the display at 0 to 40
°
C. For details, see
“ 4.9.2 7), Recommended ambient operating temperature.”
Angle: less than 5
°
Operate at 0 to 35
°
C.
When PC75Hz is input, however, operate at
0 to 30
°
C.
(Do not cover the metal fixture or the sides
of the display main body.)
Angle: 5
°
or more
May be used between 0 to 40
°
C.
When PC75Hz is input, however, operate at
0 to 30
°
C.
(Do not cover the metal fixture or the sides
of the display main body.)
• Recommended ambient operating temperature (in the open state)
Wall
Wall
5
°
or more (117mm or more from Wall)
* The same conditions apply to the working temperature requirements for a speaker system (PDP-S03-LR).
PC-9800 (56.4Hz)
PC-9800 (70.1Hz)
VIDEO
Machintosh (66.7Hz)
VGA (60HZ)
VGA (72.8Hz, 75Hz)
Angle: Less than 5
°
0~35
°
C
0~35
°
C
0~30
°
C
Angle: Equal to or
0~40
°
C
0~40
°
C
0~35
°
C
greater than 5
°
Working temperature requirements
Summary of Contents for PDA-4002
Page 5: ...5 Features ...
Page 21: ...21 Installation procedure ...
Page 57: ...57 Special installation Installation under the floor ...
Page 69: ...69 Mounting standard metal fixtures PDK 4001 ...
Page 75: ...75 Mounting standard metal fixtures PDK 4002 ...
Page 81: ...81 Mounting standard metal fixtures PDK 4004 ...
Page 131: ...131 Mounting standard metal fixtures Precautions for installing the optional speaker ...
Page 135: ...135 Before making adjustments ...