7.2.4
LED support during alignment
Display
LED
Desig-
nation
Status
Meaning
[1]
[2]
[3]
[4]
[1]
Normal
Opera-
tion
Lights
green
Transmitter and receiver are correctly
aligned and the protected field is clear
[2]
OSSD
Lights
red
Transmitter and receiver are not cor-
rectly aligned
or
protected field is inter-
rupted by an opaque object
[3]
Restart/
Align
Lights
yellow
Final upper light beam is aligned with
the receiver lens opposite
[4]
Align
Lights
yellow
Final lower light beam is aligned with
the receiver lens opposite
LED indicators on the receiver – Meaning during alignment
7.3
Checking the safety light grid
Once the safety light grid has been installed and aligned, final inspections must be carried
out before it can be put into service.
INFORMATION
This inspection may only be carried out by qualified personnel.
}
Check that the safety light grid, including any existing muting sensors, are aligned and
attached correctly. The red LED should not light up if gentle pressure is applied to the
edges of the safety light grid.
}
Check that the safety distance complies with the requirements stated in Maintaining the
safety distance.
}
Check that the area between the safety light grid and the hazardous machine compon-
ent is inaccessible from all sides.
}
Check that the safety light grid cannot be impaired by external light sources.
}
Check that, once switched on, the safety light grid switches to a safe condition if the
protected field is accessed.
}
Violate the protected field and check that
– the OSSDs are switched off,
– the red LED lights
– the monitored machine is shut down.
}
Check that the safety light grid's response time and the machine's stopping perform-
ance meet the specifications stated under Maintaining the safety distance.
}
If muting sensors are installed:
Check that the muting sensors operate correctly. Access the protected field covered by
the muting sensors.
– The muting lamp on the safety light grid must light.