Project configuration
Operating Manual PSEN op2B/1 Series
1003357-EN-02
28
0.5
3
6
60
0.15
0.3
2.7
m
m
D
SR
D
OP
Fig.: Relationship between minimum distance and operating range
Legend
D
SR
: Minimum distance from reflective surfaces in m
D
OP
: Operating range of the safety light grid in m
5.4
Installation of several adjacent safety light grids
If several adjacent safety light grids need to be
installed, steps must be taken to ensure that
the transmitter on one safety light grid
does not interfere with the receiver on another safety
light grid.
A layout as shown in the diagram below can cause problems because the light beams from
the transmitter on the first safety light grid
will influence the receiver on the second safety
light
grid.
Fig.: Non-permitted layout of two adjacent safety light
grids
Positioning of several adjacent safety light grids:
}
Both safety light grids
must
be oriented in opposite directions
or
}
An opaque surface must be positioned between two safety light grids.