![Pilz PSEN op2B-2-050/1 Operating Manual Download Page 32](http://html1.mh-extra.com/html/pilz/psen-op2b-2-050-1/psen-op2b-2-050-1_operating-manual_1556675032.webp)
Project configuration
Operating Manual PSEN op2B/1 Series
1003357-EN-02
32
A1
B1
A1
B1
A2
B2
A2
B2
L
V
D
A-B
D
A-B
Fig.: Distances between muting sensors in the application example - 4 muting sensors
Muting in two directions
L
A1
B1
[1]
A2
B2
D
A-B
V
D
MutingOff
D
A-B
Fig.: Distances between muting sensors - 4 muting sensors
Legende
[1] Safety light grid
A1 First muting sensor on the input side
B1 Second muting sensor on the input side
A2 First muting sensor on the output side
B2 Second muting sensor on the output side