7 Start-Up
46
Version: 2.0.0
MS205Equ
C-863 Mercury Controller
Switching on the C-863
Connect the power cord of the power supply with the power socket.
The C-863 copies information from the nonvolatile memory to the volatile
memory.
The
STA
LED on the front panel of the C-863 displays the state of the C-863:
−
green: C-863 is ready for normal operation
−
off: If DIP switch 8 is in the "ON" (upper) position, the C-863 is in firmware
update mode. Otherwise the C-863 might be defective.
If DIP switch 8 is in the "OFF" (lower) position and the
STA
LED does not light
after switching-on, contact our customer service department (p. 91).
7.4 Establishing Communication
The procedure for PIMikroMove is described in the following.
INFORMATION
Use the
USB Daisy Chain
and
RS-232 Daisy Chain
tabs in the PC software for
establishing communication only if you have actually connected a daisy chain
network to the PC.
INFORMATION
A non-networked controller must have the address 1, if it is to be used in
PIMikroMove. Details see "Controller Address" (p. 43).
7.4.1 Establishing Communication via RS-232
Prerequisites
You have read and understood the General Notes on Start-Up (p. 41).
The C-863 is connected to the RS-232 interface of the PC (p. 36).
You have made the following settings with the respective DIP switches prior to
switching on the C-863 (p. 42):
−
controller address = 1
−