kitCON-161CS/JC/JI
50
PHYTEC Meßtechnik GmbH 1999 L-356e_2
Connect the kitCON-161CS/JC/JI to a Host- PC (using either the
COM1 or COM2 serial communication port) with a serial cable as
shown below:
Host-PC (COM1 or 2)
kitCON-161CS/JC/JI DB9 socket P1
RxD Pin 2
to
TxD Pin 2
TxD Pin 3
to
RxD Pin 3
GND Pin 5
to
GND Pin 5
Attach a power supply to the power-connector X5. An unregulated
8 V = to 12 V =/500 mA power source can be used to supply the
board. Use only a fixed voltage power supply and no power supply
with variable voltage. Double check the correct polarity of the socket
as shown in Figure 3. If the power supply is attached correctly the red
LED D4 will shine.
Push switch S1 to perform a reset and to start the Bootstrap Loader on
the kitCON-161CS/JC/JI.
Invoke the included terminal program using the following syntax:
flasht [BR(Baudrate)] [COM port number]
Ensure that the directory from where FLASHT.EXE is started,
contains the two files ’boot’ and ’flash’.
The Bootstrap Loader determines the baud rate automatically. Hence,
only after starting the Bootstrap Loader on the
kitCON-161CS/JC/JI, FLASHT.EXE can be started with a baud rate
of your choice. Thereafter, the Bootstrap Loader will automatically
configure the serial port for this baud rate.
Note:
Some controllers are only able to generate specific baud rates.
Hence, it is possible that the controller can not generate a baud
rate specified by the invocation of the terminal program and
transmission fails. In this case the terminal program should be
invoked again specifying a lower baud rate.
Summary of Contents for kitCON-161CS
Page 28: ...kitCON 161CS JC JI 22 PHYTEC Me technik GmbH 1999 L 356e_2...
Page 44: ...kitCON 161CS JC JI 38 PHYTEC Me technik GmbH 1999 L 356e_2...
Page 54: ...kitCON 161CS JC JI 48 PHYTEC Me technik GmbH 1999 L 356e_2...
Page 58: ...kitCON 161CS JC JI 52 PHYTEC Me technik GmbH 1999 L 356e_2...
Page 62: ...Published by PHYTEC Me technik GmbH 1999 Ordering No L 356e_2 Printed in Germany...