kitCON-161CS/JC/JI
34
PHYTEC Meßtechnik GmbH 1999 L-356e_2
4.12.4
Clock MODE S3 (switch 6, 7 and 8)
The CPU-clock can be derived either directly from the oscillator
clock or from the on-chip PLL that allows definition of a prescaler.
To determine the clock source and the prescaler port P0.13 -P0.15
must be configured with DIP-Switch S3 (switch 6, 7 and 8) during
system reset. The standard version of the kitCON-161CS/JC/JI is
equipped with a 5 MHz quartz (XT1) meaning that the frequency of
the CPU clock is 20 MHz with the default jumper setting.
Clock - Mode
S3 switch 6
S3 switch 7
S3 switch 8
XT1 x 4(2,5-6,25 MHz)
OFF*
OFF*
OFF*
XT1 x 3(3,3-8,3 MHz)
ON
OFF
OFF
XT1 x 2(5-12,5 MHz)
OFF
ON
OFF
XT1 x 5(2-5 MHz)
ON
ON
OFF
OSC1 x 1(1-25 MHz)
direct drive
ON
ON
ON
XT1 x 1.5
(6.66-16,66 MHz)
ON
OFF
ON
XT1 / 2(2-50 MHz)
OFF
ON
ON
XT1 x 2.5(4-10 MHz)
ON
ON
ON
* = Default