Pinout
PHYTEC Meßtechnik GmbH 1999 L-356e_2
19
3.6
The DB9-plug P3
The DB9-plug P3 carries either the CAN-signals of the second CAN-
Interface or of the J1850
1
-Interface. The pinout of the DB9-plug
depends on the position of jumpers JP9 and JP2. The pinout is shown
for both modes in the following.
Pinout of plug P3 if: JP2 = 1+2 and 3+4; JP9 = 2+3
DB9-plug P3: second CAN interface
Pin 2:
CAN1_L
Pin 7:
CAN1_H
Pin3, 6, 8:
GND
Figure 11:
Pinout of the DB9-plug P3 (CAN 1)(front view)
J1850
Pinout of plug P3 if: JP2 = open and JP9 = 1+2
DB9-plug P3: J1850-Interface
Pin 3:
J1850 Bus
Pin6, 8:
GND
Figure 12:
Pinout of the DB9-plug P3 (J1850)(front view)
1
2
3
4
7
6
5
8
9
1
2
3
4
7
6
5
8
9