IB IL 24 PSDO 8-PAC
PHOENIX CONTACT
7619_en_05
If the limit value of the potential jumpers U
M
and U
S
is reached (total current of U
S
and U
M
),
a new power terminal must be used.
For the behavior of the safety module in the event of an error at the supply voltage, please
refer to Section “Supply voltage errors” on page 72.
Figure 3-1
Supply U
M
with connection to functional earth ground according to EN
60204-1
DC distribution network according to IEC 61326-3-1:
A DC distribution network is a DC power supply network that supplies a complete industrial
hall with DC voltage and to which any device can be connected. A typical system or machine
distribution is not a DC distribution network. For devices that are intended for a typical sys-
tem or machine distribution, the DC connections are viewed and tested as I/O signals ac-
cording to IEC 61326-3-1.
NOTE: Module damage due to polarity reversal
Polarity reversal places a burden on the electronics and, despite protection against polar-
ity reversal, can damage the module. Therefore, polarity reversal must be prevented.
24 V DC
(PELV)
+
-
230 V
24 V
externe Sicherung
max. 8 A
U für Einspeisung am Buskoppler
oder einer Einspeiseklemme
M
GND der Einspeisung am Buskoppler
oder einer
e
76191004
U für Einspeisung am Buskoppler
oder einer Einspeiseklemme (wird in der
Sicherheitsklemme nicht benötigt)
S
External fuse
8 A, maximum
U
S
for supply at a bus coupler or a power
terminal (not required in the safety terminal)
U
M
for supply at a bus coupler or a
power terminal
GND for supply at a bus coupler or a
power terminal
WARNING:
Loss of functional safety due to parasitic voltages
Supply the supply voltages U
M
and U
S
at a bus coupler and/or a power terminal from the
same power supply unit, so that the loads of IB IL 24 PSDO 8-PAC are not affected by par-
asitic voltages in the event of an error.
NOTE: Damage to module electronics in the event of surge voltage
Do not use a DC distribution network.
Summary of Contents for IB IL 24 PSDO 8-PAC
Page 1: ...User manual IB IL 24 PSDO 8 PAC Inline module with safe digital outputs...
Page 16: ...IB IL 24 PSDO 8 PAC 16 112 PHOENIX CONTACT 7619_en_05...
Page 32: ...IB IL 24 PSDO 8 PAC 32 112 PHOENIX CONTACT 7619_en_05...
Page 38: ...IB IL 24 PSDO 8 PAC 38 112 PHOENIX CONTACT 7619_en_05...
Page 54: ...IB IL 24 PSDO 8 PAC 54 112 PHOENIX CONTACT 7619_en_05...
Page 68: ...IB IL 24 PSDO 8 PAC 68 112 PHOENIX CONTACT 7619_en_05...
Page 78: ...IB IL 24 PSDO 8 PAC 78 112 PHOENIX CONTACT 7619_en_05...
Page 80: ...IB IL 24 PSDO 8 PAC 80 112 PHOENIX CONTACT 7619_en_05...
Page 90: ...IB IL 24 PSDO 8 PAC 90 112 PHOENIX CONTACT 7619_en_05...
Page 106: ...IB IL 24 PSDO 8 PAC 106 112 PHOENIX CONTACT 7619_en_05...