67
■
In addition, a click of the right mouse button on a camera icon that has an active event will call up the following list box:
Full Screen
Clear All
Action Clear
Alarm Clear
Video Loss Clear
■
Full Screen
: displays the camera on Monitor A in full screen mode and the Cameo Grid updates appropriately. This option is
grayed out if there is a Video Loss event for this camera. If there are no active events for this camera, all other options are
grayed out.
■
Clear All
: will clear any active events for this camera. Only those events that are currently active can be selected. All others are
grayed out.
■
Multiple Events
: can be cleared individually by selecting
Action Clear
,
Alarm Clear
, or
Video Loss Clear
.
■
Action and Alarm History Buttons
: when pressed, will display all cameras that have been previously in alarm. These cameras
will highlight blue in the
Cameras In Display
section. Once either of these two buttons have been reset, all history will be
erased until new alarms occur. For the History to work, these buttons must not be pressed until actions or alarms occur.
NOTE:
History must be enabled in the
Configuration Action and Alarm Tables
.
When an alarm is triggered from either motion or an alarm input, the corresponding camera or alarm icon on the map will flash.
■
Click on the
Event Handler
button in the
GUI Map
and the Event Handler will open up. From there, you can jump to the
page on your map to see where the alarm has been triggered. When double-clicking with your left mouse key on the flashing
icon (camera or alarm icon) the following box will appear.
To learn more about the
System4
Alarm Handler,
refer to the
System4
Alarm Handler User Interface
section of this user's manual.
LTC 2650 S
YSTEM
4 M
ULTIPLEXER
GUI
M
ONITOR
A
PPLICATIONS
Summary of Contents for System4 LTC 2650/00