PFT G 5 c FU 230V
Operating Manual
Issued: 09.2007
Knauf PFT GmbH & Co. KG
20
The machine may only be connected to a worksite distribution board with 16 A and
approved 30 mA FI safety switch. The connection cable must correspond to the
H07 RN-F 3 x 2.5 mm² version.
We always recommend using the 3 x 2.5 mm², 25 m PFT power cable with safety plug
and CEE coupling (item no. 20 42 34 20).
Before the control box is connected to the power supply, the following steps must be
performed:
- Turn off the main reversing switch (1) (“0” position, lockable).
- Turn the star wheel switch (2) to “0”.
- Pull out the dummy plug (3).
Connect pump motor (10-pin plug).
Switch off the compressor. (Pull the plug)
Connect the control box to the power supply.
Now the following steps must be carried out:
Turn on the main switch