PFT G 5 c FU 230V
Operating Manual
Issued: 09.2007
Knauf PFT GmbH & Co. KG
24
Interruption of work
Observe the guidelines of the material manufacturer regarding interruptions.
It is recommended to clean the pump prior to longer interruptions. To do so, see the
corresponding step on page 20 – Measures at the end of work and when cleaning.
Every interruption of the spraying procedure results in minor irregularities of the mortar
consistency. These normalise, however, as soon as the machine has been working for
a while. Therefore, do not change the water supply each time you detect an irregularity,
but wait instead until the consistency of the material emerging from the spraying gun
is correct.
Measures at the end of work and when cleaning
WARNING!
Before removing the screw pump and opening the motor tilt flange, make absolutely
sure the pump and hoses are depressurised.
Observe the mortar pressure gauge indicator.
At the end of work, switch off the mortar supply (star wheel – turn star wheel switch to “0”)
(1).
Run the mixing tube empty.
Press the red “OFF” pushbutton (2).
Switch off compressor (3) (pull plug) and open tap on finishing plaster device.
Disconnect mortar hose (only when depressurized).
Release the snap lock (1) on the motor flange and tilt the motor.
Remove the mixing shaft (2) and clean it.
Clean the mixing area with a spatula.
Insert the cleaning shaft and mixing tube cleaner with the scrapers pointing downwards.
Close motor tilt flange and lock with snap lock; connect 7-pin coupling to control box.
Press green “ON” pushbutton approx. 5
–
10 seconds and let machine run until mixing
tube is clean.
Press red “OFF” pushbutton, remove mixer cleaner.
Install the cleaned mixing shaft.
Close the motor tilt flange and lock it with the snap lock.
2
1
3
2
Summary of Contents for G 5 c FU
Page 50: ...PFT G 5 c FU 230V Operating Manual Issued 09 2007 Knauf PFT GmbH Co KG 50 Circuit diagram...
Page 51: ...PFT G 5 c FU 230V Operating Manual Issued 09 2007 Knauf PFT GmbH Co KG 51 Circuit diagram...
Page 53: ...PFT G 5 c FU 230V Operating Manual Issued 09 2007 Knauf PFT GmbH Co KG 53...