PFT G 5 c FU 230V
Operating Manual
Issued: 09.2007
Knauf PFT GmbH & Co. KG
30
Fault – Cause – Remedy
Fault Cause Remedy
Machine will not start.
Water
- Check water supply
Water pressure too low –
- Clean dirt trap
Gauge displays pressure below
2.2 bar
- Switch on booster pump
Machine will not start.
Electricity
-Power supply okay?
-FI safety switch triggered?
-Main switch turned on?
-Fault indicator lamp lights up?
-Motor safety switch triggered?
-Self-holding button not pressed?
-Contactor
defective?
-Fuses
defective?
-Water safety switch incorrectly set?
-Pump
jammed?
Machine will not start.
Air
-
Insufficient pressure gradient in
remote control due to blocked air
pipe or blocked air nozzle tube
Clean blocked air pipe or air
nozzle tube.
Machine will not start.
-Air safety switch incorrectly set
-
Compressor connected and
switched on?
Machine will not start.
Material
(No display at flow meter)
- Too much thickened material in the
hopper or mixing area
If necessary, empty the hopper to
half-full and restart.
- Material in pump component
too dry
WARNING!
First turn off main switch and pull
plug
Water is not running.
(No display at flow meter)
-
Solenoid valve (bore in diaphragm
blocked)
-
Solenoid coil defective
-
Pressure reducing valve closed
-
Water supply blocked at pump tube
-
Needle valve closed
-
Cable to solenoid valve defective
Pump motor will not start.
-
Pump motor defective
-
Connection cable defective
-
Plug or mounted socket
defective
-
Motor safety switch defective or
triggered
Stops after running briefly.
-
Dirt trap is clogged
Clean or replace screen and
-
Pressure reducer filter is dirty
enlarge the water connection
-
Hose connection or water supply
line too small
-
Water intake line too weak or
too long
Connect additional booster pump if
necessary
Summary of Contents for G 5 c FU
Page 50: ...PFT G 5 c FU 230V Operating Manual Issued 09 2007 Knauf PFT GmbH Co KG 50 Circuit diagram...
Page 51: ...PFT G 5 c FU 230V Operating Manual Issued 09 2007 Knauf PFT GmbH Co KG 51 Circuit diagram...
Page 53: ...PFT G 5 c FU 230V Operating Manual Issued 09 2007 Knauf PFT GmbH Co KG 53...
Page 55: ...PFT G 5 c FU 230V Operating Manual Issued 09 2007 Knauf PFT GmbH Co KG 55...