PFT G 5 c FU 230V
Operating Manual
Issued: 09.2007
Knauf PFT GmbH & Co. KG
19
NOTE!
1. A D6-2L stator can be used up to 15 bar operating pressure.
2. The maximum conveying distance depends mainly on how a particular type mortar
flows. Heavy, coarse-grained mortar does not flow well. Fluid mortars, filling
compounds and floor screed have good flow characteristics.
3. Using thicker mortar hoses is recommended if you exceed an operating pressure of
15 bar.
4. Use the following original spare parts to avoid machine malfunctions and excessive
wear on the pump motor, pump shaft and pump:
PFT
rotors
PFT
stators
PFT pump shafts
PFT mortar pressure hoses
PFT
clamps
These components are compatible with one another and form a single constructive
unit together with the machine. If you do not follow these recommendations, you will
not only lose your warranty rights, but the quality of the mortar will also suffer.
Start-up
- Transport assemblies as near as possible to the object to work with
(for the assembly, see Transport).
- Lock the castor before putting the machine into service.
Clean and bleed the 3/4" water hose to clean out impurities.
Then connect the water hose to the built-in water pump.
Note
Only use clean water that is free of particulates. The minimum pressure is 2.5 bar
when the machine is running.
WARNING!
When working from the water drum, the strainer with filter screen
(item no. 20 47 50 00) must be mounted (bleed water pump).
Summary of Contents for G 5 c FU
Page 50: ...PFT G 5 c FU 230V Operating Manual Issued 09 2007 Knauf PFT GmbH Co KG 50 Circuit diagram...
Page 51: ...PFT G 5 c FU 230V Operating Manual Issued 09 2007 Knauf PFT GmbH Co KG 51 Circuit diagram...
Page 53: ...PFT G 5 c FU 230V Operating Manual Issued 09 2007 Knauf PFT GmbH Co KG 53...
Page 55: ...PFT G 5 c FU 230V Operating Manual Issued 09 2007 Knauf PFT GmbH Co KG 55...