Alcatel Vacuum Technology France - ATH 200 User’s Manual
Description
Description
The A100L pump includes a monitoring system.
This pump is fully integrated in a compact and enclosed frame which
includes:
The control panel located on the front panel.
An operating time meter showing the running time of the pump.
3 light indicators showing the pump status.
A main switch allows to start and stop the pump.
A local-remote switch.
The facility interface located on the rear panel.
Water inlet and outlet quick connect.
Inlet CDA or Nitrogen connection (Energy Saving option).
Exhaust and inlet flanges to connect the pump to the pumping
circuit.
The control interface located at the rear panel.
A remote control connector (dry contacts / 16 or 19 pin plug) to
control the pump and communicate with the process tool.
A main power connector to connect the pump to the electrical
circuit.
-
-
-
-
-
-
-
-
-
Interfaces
Front panel
Rear panel
Main power supply
Water IN
Water OUT
Exhaust
Remote control connector
Light indicators
Operating time meter
Main switch
Front panel
Facility interface
Control interface
Control panel
Rear panel
‘Loc-Rem’ switch
Inlet CDA or N2 connection
(ES option)
Inlet
adixen Vacuum Products - A100L - Dry Pump - Operating Instructions