GB 04352 - Edition 03- Nov
. 11
1/6
A 40
Alcatel Vacuum Technology France - ATH 200 User’s Manual
Technical characteristics
Characteristics
Units
A100L
A100L ES «Eco Saving»
Rotation speed
(1)
Hz
rpm
100
6000
Peak Pumping speed
m
3
/h
l/mn
cfm
100
1667
59
Typical ultimate pressure
Max. ultimate pressure
mbar/
Torr/
Pa
6.6 10
-3
/ 5 10
-3
/ 6.6 10
-1
1.2 10
-2
/ 9 10
-3
/ 1.2
7 10
-4
/ 5 10
-4
/ 7 10
-2
*
3 10
-3
/ 2 10
-3
/ 3 10
-1
*
Max. volume **
Max. cycling frequency **
m
3
sec
1
25 l every 40 sec.
Max. continuous inlet flow
slm
20
Supply voltage 3PH
(3)
V
200/208V - 3 phases - 50/60Hz
380/460 V - 3 phases -
50/60Hz
NA
Power consumption at ultimate pressure
kW
1.6
< 0.8*
Average sound level at ultimate pressure
Guaranted sound level at ultimate
pressure
dbA
dbA
55
58
52*
55*
Typical vibration level at inlet flange
[10 -1000 Hz)
G/
mm.s
-1
/
μ
m.
0.10 / 1/ 1.5
Water flow
l/h
min. 100
Water temperature
°C
min. 10 / max. 25
Gear box fluid capacity
(2)
cm
3
150
Weight
Kg / Lb
100 / 220.4
Inlet flange
ISO-KF
DN 50
Exhaust flange
ISO-KF
DN 25
Environmental conditions
Use of the product:
Altitude:
Maximum relative humidity:
Ambient operating temperature:
Transient overvoltage:
Pollution degree:
clean room
up to 2000 m
80% for temp. >31°C (87°F)
decreasing linearly to 50% at 40°C (104°F)
5 to 30° C (41 to 87°F)
category II
rate 2
(1)
Variable speed control, min. 20 Hz / max. 100 Hz.
(2)
Oil charge is filled at factory. Do not modify the oil level.
(3)
According to CE regulations, A100L can withstand a supply voltage variation of ±10%.
*
Only when ES module activated.
**
In case of larger volume and/or more frequent pumping cycles, contact us.
adixen Vacuum Products - A100L - Dry Pump - Operating Instructions