30
RCS-2 Climbing Device and Hydraulics
Assembly Instructions
C3 Maintenance
Hydraulic oil
■
Observe DGUV [German Statutory Ac-
cident Insurance] regulation 113-020.
■
Top up the hydraulic oil when the climb-
ing device is in a retracted position.
■
Observe the hydraulic oil viscosity/tem-
perature diagram.
■
Refer to the details for the appropriate
operating temperature and viscosity of
the hydraulic pump in the manufactur-
er’s assembly instructions.
Hydraulic pump
Observe the manufacturer’s assembly in-
structions for the maintenance and repair
of the hydraulic pump.
Hydraulic hoses
Observe DGUV [German Statutory Acci-
dent Insurance] regulation 113-020.
■
Maintenance and checking of hoses.
■
Laying of hoses.
■
Do not mix different hydraulic oils.
■
Make a note of the oil type used for fill-
ing (e.g. oil card).
■
If the oil type is changed, the pumps,
climbing devices and hoses need to
have an oil change.
Areas of application for PERI hydraulic oils in combination with Hydraulic Pump
RCS MAX 2 x 210bar, 380-460V
Designation
Temperature range
Cold start required under
Hydraulic oil ISO 11158 HM10
-20 °C ... +25 °C
–
Hydraulic oil ISO 11158 HVI22
-14 °C ... +50 °C
-5 °C
Hydraulic oil ISO 11158 HVI46
±0 °C ... +70 °C
+10 °C
In general, use PERI hydraulic oils within viscosity range 16 to 400 mm²/s. A cold start
is required from 200 mm²/s.