O
PERATING
S
OFTWARE
OS6.0
/
OS10.0
38
OFFSET
In the event of a "Reset/Set Value" command via the control input or the PC user
interface, the current position of the rotary encoder is transferred
in a non-volatile manner to the "OFFSET" parameter. (= zero point shift)
CIRCUMFERENCE (mm)
Value
Function
-99999999
Smallest value
0
Default value
99999999
Largest value
Sets the reference quantity in mm for an angle measurement.
The distance traveled, e.g., the extent to which to generate the subsequent
ROUND LOOP VALUE, must be set here.
Note
Only for OPERATIONAL MODE: "ANGLE"
ROUND LOOP VALUE
Sets the desired data to be generated when the previous reference quantity
CIRCUMFERENCE is reached.
Note
Only for OPERATIONAL MODE: "ANGLE"
Value
Function
1
Smallest value
360
Default value
99999999
Largest value
Value
Function
00000.001
Smallest value
01000.000
Default value
99999.999
Largest value