4.2
Frequency Mode
In this menu, the operation is defined as a frequency converter (incremental
signals). Depending on the operating mode set, only channel A or both channels
(channel A and channel B) are active.
FREQUENCY MODE
This parameter determines which operating mode of the frequency measurement
is desired.
Value Designation
Function
0
A ONLY
Single-channel frequency measurement (only for
channel A).
1
RATIO
Frequency ratio of both channels (channel B /
channel A).
Note: Interpretation of the result with four
decimal places in the /- x.xxxx
2
PERCENT
Percentage deviation from channel B to channel
A.
Note: Interpretation of the result with two decimal
places in the /- xxx.xx %
3
A + B
Frequency addition of both channels (channel A
+ channel B)
4
A - B
Frequency subtraction of both channels
(channel A - channel B)
5
A/B x 90°
Frequency measurement with A/B x 90° signal.
(Forward/backward—rotation direction
monitoring)
FREQUENCY BASE
Sets the desired base for frequency measurement (resolution).
Value
Function
0
1 Hz
(Interpretation of result in format: xxxxxxxx Hz)
1
1/10 Hz
(Interpretation of result in format: xxxxxxx.x Hz)
2
1/100 Hz
(Interpretation of result in format: xxxxxx.xx Hz)
3
1/1000 Hz
(Interpretation of result in format: xxxxx.xxx Hz)