Value Designation
Function
11
RESET MIN/MAX
Resets the minimum/maximum value
(d)
(s)
12
LOCK RELEASE
Releases the self-locking of all outputs
(d)
13
SERIAL PRINT
Sends the serial data (see "Serial Print"
parameter)
(d)
14
ACTIVATE DATA
N.A.
15
STORE DATA
N.A.
16
TESTPROGRAM
N.A.
17
CLEAR LOOP
TIME
Resets the maximum loop time
(d)
18
RESET/SET
COUNTER A
Resets/sets the counter value of channel A
to the set values in SET VALUE A—only in
"COUNTER" mode
(d)
(s)
19
RESET/SET
COUNTER B
Resets/sets the counter value of channel B
to the set value in SET VALUE B—only in
"COUNTER" mode
(d)
(s)
20
LOCK COUNTER
A
Counter (channel a) is disabled and does
not count any further pulses as long as this
command is present. —only in
"COUNTER" mode
(s)
21
LOCK COUNTER
B
Counter (channel B) is disabled and does
not count any further pulses as long as this
command is present. —only in
"COUNTER" mode
(s)
22
ZERO POSITION
Transfers the current SSI position to the
"SSI Zero" parameter (rotary encoder zero
point shift)—only in "SSI" mode
(d)
(s)
23
FACTORY
SETTINGS
The device is reset to its factory settings.
(d)
PUT 1 CONFIG
This parameter determines the switching characteristics for "Ctrl. In 1."
Value Designation
Function
0
ACTIVE LOW
Activates at "LOW" (static)
1
ACTIVE HIGH
Activates at "HIGH" (static)
2
RISING EDGE
Activates at rising edge (dynamic)
3
FALLING EDGE Activates at falling edge (dynamic)