5.2.3
Read Coils and Write Single Coil
The "Read Coils" and "Write Single Coil" functions can be used to read and
set/reset individual commands:
Coil
number
Serial
code of
the
command
Command
Function
0
54
RESET/SET
Transfers the currently detected
position value to the "SSI offset"
parameter—only in "SSI" mode
1
55
FREEZE DISPLAY Freezes the current
measurement result
2
56
TEACH ANALOG
START
Transfers the current
measurement result to the
"Analog Start" parameter
3
57
TEACH ANALOG
END
Transfers the current
measurement result to the
"Analog End" parameter
4
58
TEACH
PRESELECTION 1
Transfers the current
measurement result to the
"Preselection 1" parameter
5
59
TEACH
PRESELECTION 2
Transfers the current
measurement result to the
"Preselection 2" parameter
6
60
TEACH
PRESELECTION 3
Transfers the current
measurement result to the
"Preselection 3" parameter
7
61
TEACH
PRESELECTION 4
Transfers the current
measurement result to the
"Preselection 4" parameter
8
62
TEACH
PRESELECTION 5
Transfers the current
measurement result to the
"Preselection 5" parameter
9
63
TEACH
PRESELECTION 6
Transfers the current
measurement result to the
"Preselection 6" parameter
10
64
RESET MIN/MAX
Resets the minimum/maximum
value
11
65
LOCK RELEASE
Releases the self-locking of all
outputs