Installer manual Siata V132 - SFE - System sizing
Ref. MKT-IM-003 / B - 19.04.2017
25 / 88
4.2.2. Determining the required volume of resin
When sizing a softener, make sure that the volume of resin in the tank (bed volume) will be sufficient
so that even when the peak flow rate is reached, the velocity is still between the above values
depending on the hardness. When sizing a softener, always choose the resin volume and tank size
based on the peak flow rate but not on the nominal flow rate.
Note
Sizing on the nominal flow rate without taking the peak flow rate into account would result
in choosing smaller tank size and resin volume, and may lead in severe hardness leakage
during the service cycle when the peak flow is reached.
The maximum softened water flow rate that can produce a softener is given by the following formula:
Q
service max
= Fs
service
x BV
Knowing this required volume of resin, it is possible now determine the tank you need. Note that at
least a third of the total volume of the tank must de kept as free space so that the bed expansion
during backwash is sufficient to ensure correct cleaning of the resin.
4.2.3. Resin exchange capacity and capacity of the unit
The resin exchange capacity and capacity of the unit are two different things and should not be
confused. The resin exchange capacity is the amount of Ca
2+
and Mg
2+
that 1 liter of resin can retain,
which will depend on the resin type and salt dosage, whereas the capacity of the unit is the capacity
of the system which will depend on the volume of resin and resin exchange capacity.
Knowing the required volume of resin and the tank size, you can determine the exchange capacity of
the unit. The capacity of the unit can be expressed in a different way:
•
The mass capacity, which corresponds to the weight in equivalent CaCO
3
that can be fixed on the
resin, expressed in kg as CaCO
3
;
•
The volume capacity, which represents the maximum amount of water that can be treated
between 2 regenerations. This last capacity takes into account the hardness of the water to be
treated and is expressed in m
3
or liters;
•
The combined capacity, which represents the volume of water that can be treated between 2
regenerations if the inlet hardness is 1 °f or ° dH. This capacity is expressed in °f.m
3
or °dH.m
3
.
The unit exchange capacity depends on the amount of salt to be injected in the resin bed during the
regeneration. This amount of salt is given in grams per liter of resin. The 2 tables on the following
pages show the resin exchange capacity based on the amount of salt for a system with standard
efficiency regeneration and for a system with high efficiency regeneration.
A
with:
Q
service max
: service flow rate [m
3
/h]
Fs
service
: service velocity [BV/h]
BV : bed volume of resin [m
3
]
Summary of Contents for Siata V132 SFE
Page 1: ...SIATA V132 SFE...
Page 59: ...Installer manual Siata V132 SFE Maintenance Ref MKT IM 003 B 19 04 2017 59 88...
Page 61: ...Installer manual Siata V132 SFE Maintenance Ref MKT IM 003 B 19 04 2017 61 88...
Page 63: ...Installer manual Siata V132 SFE Maintenance Ref MKT IM 003 B 19 04 2017 63 88...
Page 65: ...Installer manual Siata V132 SFE Maintenance Ref MKT IM 003 B 19 04 2017 65 88...
Page 67: ...Installer manual Siata V132 SFE Maintenance Ref MKT IM 003 B 19 04 2017 67 88...
Page 69: ...Installer manual Siata V132 SFE Maintenance Ref MKT IM 003 B 19 04 2017 69 88...
Page 71: ...Installer manual Siata V132 SFE Maintenance Ref MKT IM 003 B 19 04 2017 71 88...
Page 73: ...Installer manual Siata V132 SFE Maintenance Ref MKT IM 003 B 19 04 2017 73 88...
Page 88: ...www pentairaquaeurope com...