Depending on the inlet water hardness, the service velocity for standard softening has to be between:
Note
Failure to respect the service velocity will lead to hardness leakage or even total softener
inefficiency.
Note that the water supply piping size may also be useful when estimating the nominal flow rate, since
the size of the piping allows a maximum flow rate to pass. Assuming the maximum velocity of water
in pipes is about 3 m/s, a good estimation for most common pressure [3 bar] and temperature [16°C]
is:
Service velocity
[bed volume per hour]
Inlet water hardness
[mg/l as CaCO
3
]
°F
°TH
°dH
8 - 40
< 350
<35
<19.6
8 - 30
350 to 450
35 - 45
19.6 - 25.2
8 -20
> 450
>45
>25.2
Piping size (internal diameter)
Max. flow rate
[in]
[mm]
[m
3
/h at 3 m/s]
0.5
12
1.22
0.75
20
3.39
1
26
5.73
1.25
32
8.69
1.5
40
13.57
2.0
50
21.20
2.5
63.5
35.2
3.0
76.2
49.2
A
Summary of Contents for Siata V132 SFE
Page 1: ...SIATA V132 SFE...
Page 59: ...Installer manual Siata V132 SFE Maintenance Ref MKT IM 003 B 19 04 2017 59 88...
Page 61: ...Installer manual Siata V132 SFE Maintenance Ref MKT IM 003 B 19 04 2017 61 88...
Page 63: ...Installer manual Siata V132 SFE Maintenance Ref MKT IM 003 B 19 04 2017 63 88...
Page 65: ...Installer manual Siata V132 SFE Maintenance Ref MKT IM 003 B 19 04 2017 65 88...
Page 67: ...Installer manual Siata V132 SFE Maintenance Ref MKT IM 003 B 19 04 2017 67 88...
Page 69: ...Installer manual Siata V132 SFE Maintenance Ref MKT IM 003 B 19 04 2017 69 88...
Page 71: ...Installer manual Siata V132 SFE Maintenance Ref MKT IM 003 B 19 04 2017 71 88...
Page 73: ...Installer manual Siata V132 SFE Maintenance Ref MKT IM 003 B 19 04 2017 73 88...
Page 88: ...www pentairaquaeurope com...