No brine draw.
Low water pressure at the inlet.
Close the outlet of the valve, check that
the pressure gauge shows a pressure
of at least 2 bars. If it is lower, the
pressure is insufficient. If the pressure
is higher than 2 bar, check the
mechanical filter which is installed
before the injector is plugged by dirt.
Remove it and clean.
Screen on the manifold is plugged by
dirt.
Remove manifold and screen and
clean thoroughly.
Plugged injector.
Remove injector, thoroughly clean the
holes in the injector and remount it.
Problems in salt / brine tank.
Thoroughly check the connection
assembly to the brine tank:
A
Check that there are no
obstructions in the connection
system.
B
Check that there is a flow when the
float is in lower position.
C
Check that there is no formation of
a salt bridge in the brine tank.
D
Check that all components of the
brine valve operate efficiently.
Issue
Cause
Reset and recovery
Summary of Contents for Siata V132 SFE
Page 1: ...SIATA V132 SFE...
Page 59: ...Installer manual Siata V132 SFE Maintenance Ref MKT IM 003 B 19 04 2017 59 88...
Page 61: ...Installer manual Siata V132 SFE Maintenance Ref MKT IM 003 B 19 04 2017 61 88...
Page 63: ...Installer manual Siata V132 SFE Maintenance Ref MKT IM 003 B 19 04 2017 63 88...
Page 65: ...Installer manual Siata V132 SFE Maintenance Ref MKT IM 003 B 19 04 2017 65 88...
Page 67: ...Installer manual Siata V132 SFE Maintenance Ref MKT IM 003 B 19 04 2017 67 88...
Page 69: ...Installer manual Siata V132 SFE Maintenance Ref MKT IM 003 B 19 04 2017 69 88...
Page 71: ...Installer manual Siata V132 SFE Maintenance Ref MKT IM 003 B 19 04 2017 71 88...
Page 73: ...Installer manual Siata V132 SFE Maintenance Ref MKT IM 003 B 19 04 2017 73 88...
Page 88: ...www pentairaquaeurope com...