Installer manual Siata V132 - SFE - Commissioning
54 / 88
Ref. MKT-IM-003 / B - 19.04.2017
Brine tank softeners
Backwash the conditioner and add the required amount of hypochlorite solution to the well of the
brine tank. The brine tank should have water in it to permit the solution to be carried into the
conditioner.
Proceed with the normal regeneration.
Calcium hypochlorite
Calcium hypochlorite, 70% available chlorine, is available in several forms including tablets and
granules. These solid materials may be used directly without dissolving before use.
Dosage
Measure two grains (~ 3 mL [0.1 ounce]) per 28.3 L (1 cubic foot).
Brine tank softeners
Backwash the conditioner and add the required amount of hypochlorite to the well of the brine tank.
The brine tank should have water in it to permit the chlorine solution from being carried into the
conditioner.
Proceed with the normal regeneration.
7.2.3. Electro chlorination
Valves or systems already equipped with an electrochlorinator device or system are supposed to be
sanitized during the brine draw phase.
Summary of Contents for Siata V132 SFE
Page 1: ...SIATA V132 SFE...
Page 59: ...Installer manual Siata V132 SFE Maintenance Ref MKT IM 003 B 19 04 2017 59 88...
Page 61: ...Installer manual Siata V132 SFE Maintenance Ref MKT IM 003 B 19 04 2017 61 88...
Page 63: ...Installer manual Siata V132 SFE Maintenance Ref MKT IM 003 B 19 04 2017 63 88...
Page 65: ...Installer manual Siata V132 SFE Maintenance Ref MKT IM 003 B 19 04 2017 65 88...
Page 67: ...Installer manual Siata V132 SFE Maintenance Ref MKT IM 003 B 19 04 2017 67 88...
Page 69: ...Installer manual Siata V132 SFE Maintenance Ref MKT IM 003 B 19 04 2017 69 88...
Page 71: ...Installer manual Siata V132 SFE Maintenance Ref MKT IM 003 B 19 04 2017 71 88...
Page 73: ...Installer manual Siata V132 SFE Maintenance Ref MKT IM 003 B 19 04 2017 73 88...
Page 88: ...www pentairaquaeurope com...