To calculate the system mass capacity:
M
capacity
= V
resin
x C
resin ex
To calculate the system combined capacity:
C
capacity
= V
resin
x C
cor resin exi
To calculate the system volume capacity:
V
capacity
= M
capacity
/ TH
inlet
or
V
capacity
= C
capacity
/ TH
inlet
Caution
If M
capcacity
is in [kg] the value need to be multiplied by 1000.
Note
If a mixing device is set on the valve, the water hardness will be different.
Having determined the previous capacity allows the operator to know the service cycle duration.
with:
M
capacity
: system mass capacity [g as CaCO3]]
V
resin
: volume of resin [L]
C
resin ex
: resin exchange capacity [g/L
resin
as CaCO
3
]
with:
C
capacity
: system combined capacity [°F.m
3
or °dH.m
3
]
V
resin
: volume of resin [L]
C
cor resin ex
: corresponding resin exchange capacity [°F.m
3
/L or °dH.m
3
/L]
with:
V
capacity
: system volume capacity [m
3
]
M
capacity
: system mass capacity [kg as CaCO
3
] or [°F.m
3
or °dH.m
3
]
C
capacity
: system combined capacity [°F.m
3
or °dH.m
3
]
TH
inlet
: inlet water hardness [mg/L as CaCO3] or [°F or °dH]
A
A
Summary of Contents for Siata V132 SFE
Page 1: ...SIATA V132 SFE...
Page 59: ...Installer manual Siata V132 SFE Maintenance Ref MKT IM 003 B 19 04 2017 59 88...
Page 61: ...Installer manual Siata V132 SFE Maintenance Ref MKT IM 003 B 19 04 2017 61 88...
Page 63: ...Installer manual Siata V132 SFE Maintenance Ref MKT IM 003 B 19 04 2017 63 88...
Page 65: ...Installer manual Siata V132 SFE Maintenance Ref MKT IM 003 B 19 04 2017 65 88...
Page 67: ...Installer manual Siata V132 SFE Maintenance Ref MKT IM 003 B 19 04 2017 67 88...
Page 69: ...Installer manual Siata V132 SFE Maintenance Ref MKT IM 003 B 19 04 2017 69 88...
Page 71: ...Installer manual Siata V132 SFE Maintenance Ref MKT IM 003 B 19 04 2017 71 88...
Page 73: ...Installer manual Siata V132 SFE Maintenance Ref MKT IM 003 B 19 04 2017 73 88...
Page 88: ...www pentairaquaeurope com...