4 • Basic Application Configurations
Model 3086 G.SHDSL Integrated Access Device User Guide
44
Serial Port
Switch S2-8
S2-8 activates configuration of Model 3086 via DIP switches. Any time the user desires to modify the 3086
configuration available through dip switches, make the changes to the corresponding switches and then set S2-
8, from On to Off position, wait 3-4 seconds and set back to the On position. Changes made to configuration
via DIP switches will not take effect if S2-8 isn’t toggled.
Switch Bank S3
The table below shows the default configuration for switch S3. A description of S3 options follows this table.
On
On
Off
Off
On
On
On
1536
On
On
Off
Off
On
On
Off
1600
On
On
Off
Off
On
Off
On
1664
On
On
Off
Off
On
Off
Off
1728
On
On
Off
Off
Off
On
On
1792
On
On
Off
Off
Off
On
Off
1856
On
On
Off
Off
Off
Off
On
1920
On
On
Off
Off
Off
Off
Off
1984
On
Off
On
On
On
On
On
2048
On
Off
On
On
On
On
Off
2112
On
Off
On
On
On
Off
On
2176
On
Off
On
On
On
Off
Off
2240
On
Off
On
On
Off
On
On
2304
S2-8
Condition
ON->Off->ON
Implements switch configuration (toggled ON/OFF)
Table 5. S3 Summary Table
Switch Position
Function
Factory Default
Selected Option
S3-1
CO/CP Selection
On
CO
S3-2
Reserved
On
Reserved
S3-3
Clock
On
External
S3-4
Reserved
On
Reserved
S3-5
Reserved
On
Reserved
S3-6
Annex
Off = Annex A
On = Annex B
Annex B
S3-7
Reserved
On
Reserved
S3-8
Reserved
On
Reserved
S7
S6
S5
S4
S3
S2
S1
Serial Port
Data Rate (kbps)