Hardware installation
31
Model 3086 G.SHDSL Integrated Access Device User Guide
3 • Quick Start Installation
2. Verify that the AC power cord included with your 3086 is compatible with local standards. If it is not,
refer to Chapter 10, “Contacting Patton for assistance” on page 29 to find out how to replace it with a
compatible power cord.
3. Connect the male end of the power cord to an appropriate power outlet.
4. Verify that the green POWER LED is lit.
5. Unplug the AC power cord from the Model 3086 to power down the unit.
Connecting network cables
Except for the Console port, all connectors are on the rear panel of the ipRocketLink with the exception of the
power connection. The Ethernet port is Green and the Line is Yellow. The Console port is the only electrical
connection on the front panel.
Do the following:
1. Connect the DB9-RJ45 adapter to the DB-9 serial port on the PC or dumb terminal. Use the RJ45-RJ45
straight-through cable between the adapter and the red marked RJ45 port on the 3086 IAD.
2. Do NOT connect the IAD to the Ethernet LAN now.
3. On the PC, start a HyperTerminal session at 9600 bps, 8 data bits, 1 stop bit, and no parity.
4. Plug the AC power cord into the Model 3086 to power up the IAD.
5. Type superuser for Login:, and press Enter.
6. Then type superuser for the password, press Enter.
7. A message will display, “Login Successful.” By typing the character “?”, all the commands will be dis-
played. Any commands parameters may be seen by entering the command followed by a space and a ques-
tion mark.
→
ethernet ?
[The following parameters appear]
add
delete
set
show
list
clear
IP address Quick Start modification
The first parameter to change is the IP address from the default IP address of 192.168.1.1/24 (for the CP
units) or 192.168.200.11 (for CO units) to your selected IP address. Follow these steps. Comments are in
brackets […].
→
ip list interfaces <enter>
[lists the characteristics of the different interfaces]
The 3086 power supply automatically adjusts to accept an input
voltage from 100 to 240 VAC (50/60 Hz).
Verify that the proper voltage is present before plugging the
power cord into the receptacle. Failure to do so could result in
equipment damage.