Rebuilding the NMS Server
155
FS6300 NMS Administrator’s Reference Guide
A • Recovering the NMS Server from Disk
2.
Select
Add/Remove Spare
from the top of the screen. Assign each drive in the list as a spare for array use
later in the process.
Figure 124. Assign Both Drives as Spares
3.
Press the Power button to shut down the NMS server. Remove one of the disks and label the drive as
“
system1 spare
”. Then, replace the empty bay with the provided “
RMA recovery drive
.”
4.
Continue the process with the procedure in the next section,
“Rebuilding the NMS Server”
.
Rebuilding the NMS Server
Before following the steps in this section, ensure that you have assigned the spare drives and have removed and
replaced one of the drives with the
RMA recovery drive
(as instructed in the section
“Assigning Spare Drives”
on page 154).
To rebuild the NMS server:
1.
Press the power button to turn on the NMS server. At the RAID initialize screen, press the
CTRL
and
H
keys at the same time to start the BIOS Setting Utility (
Figure 119
).
2.
The RAID Controller automatically begins the rebuilding process. To view the progress, select
View >
RAID Array
from the top of the screen.
Figure 125. View > RAID Array
Leave the system on the
RAID Array
screen (
Figure 126
) and wait for the rebuilding progress to reach
100%. The rebuilding process usually takes about 1.5 hours. When the progress finishes, the array status
will change to “
Normal
”.