Assigning Spare Drives
154
FS6300 NMS Administrator’s Reference Guide
A • Recovering the NMS Server from Disk
5.
Select
Settings > Parameter Setting
from the top of the screen. Enable
Auto Rebuild
(if disabled).
Figure 122. Enable Auto Rebuild
Note
If the intention is to only upgrade the RAID controller and not
restore the NMS server, restart the system now and resume normal
use. To continue the procedure for restoring the NMS server, follow
the instructions in the next section,
“Assigning Spare Drives”
.
Assigning Spare Drives
Creating a spare drive is the next procedure in the process to restore the NMS server from disk. Ensure that you
have verified the firmware version and enabled auto rebuild in the BIOS Setting Utility (as instructed in the
section
“Upgrading the RAID Controller”
on page 152) before assigning spare drives.
1.
In the BIOS Setting Utility, select
Delete
at the top of the screen. Select the
FS6300NMS
entry and press
Enter
. The Array list should now be empty.
Figure 123. Delete FS6300NMS Array